Logo Logo
FAQ
Contact
Switch language to German
System design and experimental validation of a novel small-animal in-beam PET scanner for hadrontherapy range verification
System design and experimental validation of a novel small-animal in-beam PET scanner for hadrontherapy range verification
This thesis develops and validates a PET-based framework for online proton-beam range verification in small-animal models, with an extension to radioactive ion beams. A novel spherical in-beam PET scanner, composed of 56 pyramidal-stepped DOI-capable LYSO scintillator blocks, was designed and characterized through Monte Carlo simulations (Geant4--MEGAlib) and experimental campaigns. A custom list-mode ML-EM reconstruction pipeline, integrating sensitivity and motion corrections, was implemented for online analysis, explicitly accounting for the translation and rotation of the mouse during treatment. The system demonstrates sub-millimeter spatial resolution and sensitivity, enabling robust range verification even under low-statistics conditions typical of realistic preclinical irradiations. Beam-time experiments were performed at the Danish Center for Particle Therapy (DCPT, Aarhus, DK) and at the GSI Helmholtz Center (Darmstadt, DE) to validate detector performance, coincidence selection, and image reconstruction, followed by application in-vivo on irradiated mice. The results suggest that the proposed PET framework is feasible for high-precision preclinical range monitoring in both proton and radioactive ion beams., Diese Dissertation entwickelt und validiert ein PET-basiertes Verfahren zur Online-Reichweitenverifikation von Protonenstrahlen in Kleintiermodellen, erweitert um die radioaktiver Ionenstrahlen. Ein neuartiger sphärischer In-Beam-PET-Scanner, bestehend aus 56 pyramidal-gestuften, DOI-fähigen LYSO-Szintillatorblöcken, wurde entworfen und durch Monte-Carlo-Simulationen (Geant4--MEGAlib) sowie experimentelle Messkampagnen charakterisiert. Eine maßgeschneiderte List-Mode-ML-EM Rekonstruktionskette, mit integrierter Sensitivitäts- und Bewegungskorrektur, wurde für die Online-Analyse implementiert und berücksichtigt explizit die Translation und Rotation der Maus während der Bestrahlung. Das System zeigt eine Sub-Millimeter-Ortsauflösung und eine Sensitivität, die eine robuste Reichweitenverifikation auch unter den typischerweise niedrigen Ereignisstatistiken realistischer präklinischer Bestrahlungen ermöglicht. Strahlzeit-Experimente wurden am Danish Center for Particle Therapy (DCPT, Aarhus, DK) sowie am GSI Helmholtz Centre (Darmstadt, DE) durchgeführt, um die Detektorleistung, Koinzidenzselektion und Bildrekonstruktion zu validieren, gefolgt von der in-vivo Anwendung an bestrahlten Mäusen. Die Ergebnisse deuten darauf hin, dass das vorgeschlagene PET-Verfahren für das hochpräzise präklinische Reichweitenmonitoring sowohl mit Protonen- als auch mit radioaktiven Ionenstrahlen realisierbar ist.
Not available
Lovatti, Giulio
2026
English
Universitätsbibliothek der Ludwig-Maximilians-Universität München
Lovatti, Giulio (2026): System design and experimental validation of a novel small-animal in-beam PET scanner for hadrontherapy range verification. Dissertation, LMU München: Faculty of Physics
[thumbnail of lovatti_giulio.pdf]
Preview
PDF
lovatti_giulio.pdf

15MB

Abstract

This thesis develops and validates a PET-based framework for online proton-beam range verification in small-animal models, with an extension to radioactive ion beams. A novel spherical in-beam PET scanner, composed of 56 pyramidal-stepped DOI-capable LYSO scintillator blocks, was designed and characterized through Monte Carlo simulations (Geant4--MEGAlib) and experimental campaigns. A custom list-mode ML-EM reconstruction pipeline, integrating sensitivity and motion corrections, was implemented for online analysis, explicitly accounting for the translation and rotation of the mouse during treatment. The system demonstrates sub-millimeter spatial resolution and sensitivity, enabling robust range verification even under low-statistics conditions typical of realistic preclinical irradiations. Beam-time experiments were performed at the Danish Center for Particle Therapy (DCPT, Aarhus, DK) and at the GSI Helmholtz Center (Darmstadt, DE) to validate detector performance, coincidence selection, and image reconstruction, followed by application in-vivo on irradiated mice. The results suggest that the proposed PET framework is feasible for high-precision preclinical range monitoring in both proton and radioactive ion beams.

Abstract

Diese Dissertation entwickelt und validiert ein PET-basiertes Verfahren zur Online-Reichweitenverifikation von Protonenstrahlen in Kleintiermodellen, erweitert um die radioaktiver Ionenstrahlen. Ein neuartiger sphärischer In-Beam-PET-Scanner, bestehend aus 56 pyramidal-gestuften, DOI-fähigen LYSO-Szintillatorblöcken, wurde entworfen und durch Monte-Carlo-Simulationen (Geant4--MEGAlib) sowie experimentelle Messkampagnen charakterisiert. Eine maßgeschneiderte List-Mode-ML-EM Rekonstruktionskette, mit integrierter Sensitivitäts- und Bewegungskorrektur, wurde für die Online-Analyse implementiert und berücksichtigt explizit die Translation und Rotation der Maus während der Bestrahlung. Das System zeigt eine Sub-Millimeter-Ortsauflösung und eine Sensitivität, die eine robuste Reichweitenverifikation auch unter den typischerweise niedrigen Ereignisstatistiken realistischer präklinischer Bestrahlungen ermöglicht. Strahlzeit-Experimente wurden am Danish Center for Particle Therapy (DCPT, Aarhus, DK) sowie am GSI Helmholtz Centre (Darmstadt, DE) durchgeführt, um die Detektorleistung, Koinzidenzselektion und Bildrekonstruktion zu validieren, gefolgt von der in-vivo Anwendung an bestrahlten Mäusen. Die Ergebnisse deuten darauf hin, dass das vorgeschlagene PET-Verfahren für das hochpräzise präklinische Reichweitenmonitoring sowohl mit Protonen- als auch mit radioaktiven Ionenstrahlen realisierbar ist.